maipu maipu

SEARCH
Switch > DataCenter Switch > NSS7810-24QV16QE 200G Data Center Switch

NSS7810-24QV16QE 200G Data Center Switch

NSS7810-24QV16QE is a new generation 400G VxLAN spine switch designed for enterprise data center and campus LAN networks, providing high-throughput, high-density 100/200GE and 400GE interfaces, larger buffer and lower latency. By using Maipu MyPowerOS software platform, NSS7810-24QV16QE provide rich data center service features and management capability.

NSS7810-24QV16QE realize large buffer of the interfaces, meeting the burst flow forwarding without packet loss; provide the M-LAG technology for virtualization scenarios; provide the modular power and fan design for high reliability. The key components adopt "overvoltage" designs to ensure that the product has the strong ability of continuous operation.

NSS7810-24QV16QE adopts advanced hardware architecture with up to 24*100/200GE+16*400GE ports. It can work together with NSS5830/5930 VxLAN leaf switches to build a complete, scalable, virtualized fabric network that meets the data center requirements. Meanwhile, NSS7810-24QV16QE can also be deployed as aggregation or core switches for enterprise campus LAN networks.

NSS7810-24QV16QE supports 24*Port QSFP56 100/200G interfaces, 16*Port QSFP112 400G interfaces, 6*Fan slots, 2*Power slots.

 

(Note: The product information may not be latest. For the latest, please contact overseas@maipu.com)

Product Features

· High-density 100/200GE and 400GE ports

The NSS7810-24QV16QE adopts advanced hardware architecture with 24*100/200GE and 16*400GE interfaces in compact 1U device. The port combination fully satisfies the interface density requirement of data center scenarios. NSS7810-24QV16QE can work with NSS5830/NSS5930 leaf switches to build a non-blocking network architecture.

 

· M-LAG for cross-device link aggregation

The NSS7810-24QV16QE supports multi-chassis link aggregation group (M-LAG), which enables links of multiple switches to aggregate into one to implement cross-device link backup. The rest of switches in the M-LAG group are working actively regardless any switch failure. During the upgrade, other switches in the system take over traffic forwarding to ensure uninterrupted services.

 

 · VxLAN for Layer2/3 Virtualized Deployment

The NSS7810-24QV16QE can work with the industry's mainstream virtualization platforms and acts a hardware gateway on an VxLAN overlay network. Virtual extensible LANs (VxLAN), a common network virtualization overlay protocol that expands the layer 2 network address space from 4,000 to 16 million. NSS7810-24QV16QE supports BGP-EVPN, which is used as the overlay control plane and provides virtual connectivity between different layer 2/3 domains over an IP or MPLS network.

 

 ·  RoCEv2 Lossless Ethernet Technology

The NSS7810-24QV16QE supports lossless Ethernet (RoCEv2) features such as Priority-based Flow Control (PFC) and Explicit Congestion Notification (ECN) control algorithms which can avoid packet loss and message retransmission that may occur in traditional Ethernet protocols when encountering network congestion, reduce network latency and jitter, and thus achieve higher performance and lower latency.

 

 ·   Telemetry for intelligent OAM

The NSS7810-24QV16QE provides telemetry technology to collect device data in real time and send the management data to customer network analyzer platform. Telemetry systems, done properly, play an important role in providing you with information about the health of your network, so you can respond intelligently to prevent hardware failure and network downtime. It can help customers to identify and analyze network problems which affect user experience. 

 

·  Netconf & Restfonf API Integration

The NSS7810-24QV16QE supports NETCONF and Restconf API and can work with 3rd party SDN controller for simplified device remote configuration.

 

 ·   Reliable hardware design and energy-saving

The NSS7810-24QV16QE uses a standard airflow design which isolates cold air channels from hot air channels. This design improves heat dissipation efficiency and meets design requirements of data center. It adopts hot swap redundant power modules and fans which ensure hardware reliability and non-stopping operation. The fan speed can be adjusted dynamically based on system workload.

 

 ·  Free Licensing Policy

Maipu always insists on “One-time investment” free license policy, the standard features and advanced features will be never divided to different version. For any new firmware version, Maipu will share to customers without extra charge. Compared with other manufacturers, Maipu free license policy can better protect users' short-term and long-term investment.

Product Specifications

Product Model

NSS7810-24QV16QE

Hardware specification 

Interfaces

24*100/200G QSFP56 + 16*400G QSFP112 Interfaces

Power Supply Slots

2

FAN Module Slots

6

Management interface

One Console port, One management Ethernet port, One USB interface

Switching capacity

22.4Tbps

Power Supply

Input voltage (AC): 100V ~ 240V, 50Hz ~ 60Hz

Temperature

Work temperature: 0 to 50

Storage temperature: -40 to 70

Humidity

Work humidity: 10% to 90%, no-condensing

Storage humidity: 5% to 95%, no-condensing

Dimension(W*D*H)

442mm*560mm*44.2mm

MTBF

>100, 000 hours

Software specification 

Standard L2 protocol

Interface

Port Type UNI/NNI, Port Speed, Port MTU, Port Loopback, Loopback interface, Tunnel interface, Null interface, VXLAN interface

Ethernet Switching

LACP Link aggregation, LACP Port Priority, LACP Load Balance, LACP Rate Monitor, LACP Debug, Port isolation, QinQ, VLAN mapping, Super VLAN, PVLAN, Voice VLAN, STP, MSTP, Loopback-detection, Error-disable, GVRP, MLAG, MLAG Lite, VLAN isolation

Standard L3 protocol

IP Protocol

ARP, DHCP, DHCPv6, DHCP Server, DHCPv6 Server, DHCPv6 Client, DHCP Relay, DHCPv6 Relay, DHCP Option82, DNS, GRE, IPIP, IPv6 over IPv4, ISATAP, IPv4 over IPv6, IPv6 over IPv6

Routing Protocol

Static route for IPv4&IPv6, RIPv1/v2, RIPng, OSPFv2, OSPFv3, IS-IS, IS-ISv6, BGP, BGPv6, Policy Route, MP-BGP

Multicast

L2 multicast

IGMP Snooping, IGMP Snooping over VxLAN, multicast VLAN (MVR, MVP), MLD Snooping, Router-alert Option

L3 multicast

IGMPv1/v2/v3, MLDv1/v2, PIM-SM, PIM-DM, PIM-SSM, IPv6 PIM-SM, IPv6 PIM-SSM, MSDP, IGMP Group Filter, MLD Group Filter

QoS & ACL

QoS

802.1p, DSCP, Priority Mapping, SP, WRR, WDRR, SP+WRR, SP+WDRR, WRED, Flow classification, Traffic monitoring, Traffic shaping, Congestion management, Congestion avoidance, Flow-based mirroring

ACL

Standard IP ACL, extended IP ACL, standard MAC ACL, extended MAC ACL, extended Hybrid ACL, Standard IPv6 ACL, extended IPv6 ACL

Data center feature

VxLAN

VXLAN, EVPN

Lossless Ethernet

ECN, ETS, PFC, etc.

MPLS

BGP MPLS

MPLS LDP, MPLS GR, M-VRF, MPLS L3VPN, MPLS OAM, IPv6 MPLS L3VPN

Virtualization

Stacking

H-VST, M-VST, M-LAG

MAD

MAD LACP, MAD BFD, MAD Fast-hello

Security & Network Reliability

Security

ARP Check, AARF, AARF ARP-Guard, CPU Protection, Port Security, IP Source Guard, IPv6 Source Guard, ND-Snooping, DHCP Snooping, DHCPv6 Snooping, Dynamic ARP Inspection, AARF, Host Guard, PPPoE+, AAA, 802.1x, Portal Authentication, Anti-attack detect|drop|flood|log, URPF

Network Reliability

HA, ULFD, ERPS, ULPP, Monitor Link, VRRP, VRRPv3, VBRP, BFD, EEP

Management

Network Management

SNMP v1/v2/v3, MIB, RMON, SYSLOG, DNS, CLI, Telnet, FTP/TFTP, Debug, NTP, Keepalive, Openflow

Network Monitoring

SPAN, RSPAN, ERSPAN, VLAN SPAN, IPFIX, sFlow, LLDP, IP-SLA, CWMP, Telemetry, Netconf, BSM, MOD

Order Information

Product model

Description

NSS7810-24QV16QE  Series Host

NSS7810-24QV16QE

24*100/200G QSFP56 Interfaces, 16*400G QSFP112 interfaces, 6*Fan slots, 2*Power slots

Power Modules

AD1300M-HV1B

CPRS AC Power Supply, AC input 100-127V/12A, output 12V/1000W or AC input 200-240V/8A, output 12V/1300W, current sharing, supporting hot-swap, Air front in rear out. (Note: Need work together with FAN-01K-01B)

AD1300M-HV0F

CPRS AC Power Supply, AC input 100-127V/12A, output 12V/1000W or AC input 200-240V/8A, output 12V/1300W, current sharing, supporting hot-swap, Air rear in front out. (Note: Need work together with FAN-01K-01F)

DD1300M-5V1B

CPRS DC Power Supply, DC input 40-72V/40-22A, output 12V/106A current sharing, supporting hot-swap, Air front in rear out. (Note: Need work together with FAN-01K-01B)

DD1300M-5V0F

CPRS DC Power Supply, DC input 40-72V/40-22A, output 12V/106A current sharing, supporting hot-swap, Air rear in front out. (Note: Need work together with FAN-01K-01F)

FAN Modules

FAN-01K-01B

FAN-01K-01B FAN Module, Hot-swappable, Air front in rear out

FAN-01K-01F

FAN-01K-01F FAN Module, Hot-swappable, Air rear in front out

Fiber Transceivers

SFP-M1-L192P8

10G SFP+, 850nm, 300m, LC, DDM, Multi-Mode

SFP-S1-L192P3

10G SFP+, 1310nm, 10km, LC, DDM, Single-Mode

SFP-S4-L192P5

10G SFP+, 1550nm, 40km, LC, DDM, Single-Mode

SFP-S8-L192P5

10G SFP+, 1550nm, 80km, LC, DDM, Single-Mode

SFP-XGEA

10G BASE-T RJ45, 30m

SFP28-M1-L480C8D

25G SFP28, 850nm, 100m, LC, DDM, Multi-Mode

SFP28-S1-L480C3D

25G SFP28, 1310nm, 10km, LC, DDM, Single-Mode

QSFP28-M1-M1920C8D

100Gbps QSFP28, 850nm, 100m, MPO, DDM, Multi-Mode

QSFP28-M1-100G-LD3-S

100Gbps QSFP28, 1310nm, 100m, LC, DDM, Multi-Mode

QSFP28-S1-L1920C3D

100Gbps QSFP28, 1310nm, 10Km, LC, DDM, Single-Mode

QSFP28-S4-100G-LD7

100Gbps QSFP28, 1550nm, 40km, LC, DDM, Single-Mode

QSFP56-M1-200G-MD8

200Gbps QSFP56, 850nm, 100m, MPO, DDM, Multi-Mode

QSFP112-M1-400G-MD8

400Gbps QSFP112, 850nm, 50m, MPO12-APC, DDM, Multi-Mode

:NSS7810-24QV16QE 200G Data Center Switch Datasheet-20250507