maipu maipu

SEARCH
Switch > Campus Switch > NSS6600 Series L3 MPLS Core Switch

NSS6600 Series L3 MPLS Core Switch

NSS6600 series switch is a high-performance stackable L3 distribution routing switch developed by Maipu. It is applied in enterprise campus network and easy to deploy Layer3 switching solution that offers enhanced security and 10GE/40GE uplinks, RIP/OSPF/BGP/IS-IS, L2&L3 Multicast, VST stacking enabled and flexible management.

NSS6600 series switch can be used as L3 distribution devices on large-sized campus networks. They can also be used as core devices on small and medium-sized campus networks. The switches help build highly reliable enterprise campus networks that are easy to expand and manage.

NSS6600 series switch includes NSS6600-04, NSS6600-06, NSS6600-10 three models.

 

(Note: The product information may not be latest. For the latest, please contact overseas@maipu.com) 

 

 

 

Product Features

l  High-Density Interfaces Line Cards

NSS6600 series provide maximum 384*1GE, 384*10GE, 96*40GE interfaces. The port combination fully satisfies the interface density requirement of campus network scenarios.

l  Highly Reliable Enterprise-class Hardware Design

NSS6600 has enterprise-class reliability and stability to ensure long-term service continuity. Redundant MPUs work in 1+1 hot backup mode. Redundant SFUs work in 1+1 balance mode. Redundant power supplies support work in N+1 hot backup and redundant fan trays design.

l  Intelligent stacking technology

NSS6600 series switch supports Maipu VST stacking function. Two NSS6600 supporting stacking feature are combined to form a virtual switch logically. VST stacking system improves the device-class reliability by redundant backup among multiple member devices and improves the link-class reliability by the link aggregation function across devices. VST provides a powerful expansion capability for campus network.

l  High availability

NSS6600 series switch not only supports the traditional STP/RSTP/MSTP spanning tree protocol, but also supports the G.8032 international standard G.8032 protocol issued by ITU-T. This standard can realize 50ms millisecond fast protection switching of Ethernet ring network.

The NSS6600 also supports Virtual Router Redundancy Protocol (VRRP), which implement backup of uplinks. One switch can connect to multiple aggregation switches through multiple links, significantly improving the reliability of access devices.

l  Perfect security policy

NSS6600 series switch provides various security policies such as user authority/identity authentication, port security, port rate limitation, port monitoring, ACL, loopback detection, and 802.1X authentication; provides various protect mechanisms for user access and network security. It has perfect security function design and supports MAC+IP+VLAN binding and 802.1X authentication security policies, and anti-network storm attack, anti DOS/DDOS attack, anti ARP attack, and anti-network protocol packet attack security technologies. In this way, the attacks and virus can be prevented, and it is more suitable for large-scale, multi-service and complicated-traffic networks.

l  Advanced QoS

NSS6600 series switch supports eight queues per port and the queue scheduling policies such as SP, RR, WRR, and WDRR; rich priority mappings including 802.1p, COS, DSCP; Kbps-level port traffic rate restriction and carriers can limit the rate according to the time period; Tail Drop and RED packet loss algorithm.

l  Zero Touch Implementing

NSS6600 series support Zero Touch Provisioning (ZTP). It enables the switch to automatically obtain and load version files from file server through DHCP server or USB flash disk.

l  IPv4&IPv6 Dual-stack ability

NSS6600 series switch comes with IPv4/IPv6 dual-stack platform which provides hardware-based IPv4/IPv6 wire-speed forwarding and IPv4/IPv6 Layer3 routing protocols (RIPng, OSPFv3, BGP4+ and IS-IS for IPv6). With these IPv6 features, the NSS6600 can be deployed on a pure IPv4 network, a pure IPv6 network, or a shared IPv4/IPv6 network, helping achieve IPv4-to-IPv6 transition.

l  SDN Controller Management

NSS6600 can be managed by Maipu BD-Campus controller, which is an integrated SDN platform for campus network. It simplifies campus network security, deployment, and management with the latest software-defined network technologies. It helps the network team complete most of the work on the BD-Campus controller platform. Compared with traditional methods, BD-Campus solution can make the network deployment faster, maintain the network easier, troubleshoot much more efficient, and save customer's overall cost.

l  Free Licensing Policy

Maipu always insists on “One-time investment” free license policy, the standard features and advanced features will be never divided to different version. For any new firmware version, Maipu will share to customers without extra charge. Compared with other manufacturers, Maipu free license policy can better protect users' short-term and long-term investment.

Product Specifications

Product model

NSS6600-04

NSS6600-06

NSS6600-10

Version

V1

V2

V2

Hardware specification

Hardware Architecture

Full Mesh

Distribution

Distribution

Control Engine Slots

2

2

2

Switching Engine Slots

N/A

2

2

Service Card Slots

4

4

8

Control Engine Model

NSM66-MPUB

NSM66-MPUE

NSM66-MPUE

Switching Engine Model

N/A

NSM66-SFUB

NSM66-SFUD

NSM66-SFUB

NSM66-SFUD

Switching Capacity

1Tbps

3.84Tbps

7.68Tbps

Flash

8G

Memory

4G

Jumbo Frame

12K

MAC Address Entry

131K/383K

IPv4 Routing Entry

81K/131K

IGMP Snooping Entry

3K/5K

PIM Entry

3K/5K

ARP Entry

63K

MSTP Instance

64

Max. ECMP Path

64

VRF Entry

1K

VRRP Group

255

Power Slots

2

4

4

FAN Array Slots

1

2

2

Air Flow

Front-to-Back

Front-to-Back

Front-to-Back

PoE Standard

N/A

802.3 af/at/bt

802.3 af/at/bt

Power Input

Input voltage AC: 100V ~ 240V, 50Hz ~ 60Hz

N/A

Input voltage DC:42V~72V

Temperature

Work temperature: 0 to 50

Storage temperature: -40 to 70

Humidity

Work humidity: 10% to 90%, no-condensing

Storage humidity: 5% to 95%, no-condensing

MTBF

>100, 000 hours

Software Specification

Standard L2 protocol

Interface

Port Type UNI/NNI, Port Speed, Port MTU, Port Loopback, Loopback interface, Tunnel interface, Null interface, VXLAN interface

Ethernet Switching

LACP Link aggregation, LACP Port Priority, LACP Load Balance, LACP Rate Monitor, LACP Debug, Port isolation, QinQ, VLAN mapping, Super VLAN, PVLAN, Voice VLAN, STP, MSTP, G.8032, Loopback-detection, Error-disable, GVRP, MLAG, VLAN isolation

Standard L3 protocol

IP Protocol

ARP, DHCP, DHCPv6, DHCP Server, DHCPv6 Server, DHCPv6 Client, DHCP Relay, DHCPv6 Relay, DHCP Option82, DNS, GRE, IPIP, IPv6 over IPv4, ISATAP, IPv4 over IPv6, IPv6 over IPv6

Routing Protocol

Static route for IPv4&IPv6, RIPv1/v2, RIPng, OSPFv2, OSPFv3, IS-IS, IS-ISv6, BGP, BGPv6, Policy Route

Multicast

L2 multicast

IGMPv1/v2/v3 Snooping, multicast VLAN

L3 multicast

IGMPv1/v2/v3, PIM-SM, IPv6 PIM-SM, IPv6 PIM-SSM, PIM-DM, MSDP, MLD-snooping

QoS & ACL

QoS

802.1p, DSCP, and other priority mapping, SP, WRED, WDRR, Flow classification, Traffic monitoring, Traffic shaping, Congestion management, Congestion avoidance, Flow-based mirroring

ACL

Standard IP ACL, extended IP ACL, standard MAC ACL, extended MAC ACL, extended Hybrid ACL, Standard IPv6 ACL, extended IPv6 ACL

Virtualization

Stacking

H-VST, M-VST, M-LAG

MAD

MAD LACP, MAD BFD, MAD Fast-hello

Zero Touch Provisioning

ZTP mode A

ZTP provisioning through DHCP server

ZTP mode B

ZTP provisioning trough USB flash disk

MPLS VPN

L3 BGP MPLS

MPLS LDP, MPLS L3 VPN, MPLS Option-A & Option-B, MPLS Ping/traceroute

MCE

Multi-VRF

Data Center

VxLAN

Static VxLAN, EVPN VxLAN

Security & Network Reliability

Security

ARP Check, AARF, AARF ARP-Guard, CPU Protection, Port Security, IP Source Guard, IPv6 Source Guard, ND-Snooping, DHCP Snooping, DHCPv6 Snooping, Dynamic ARP Inspection, Host Guard, PPPoE+, AAA, 802.1x, Portal, Anti-attack detect|drop|flood|log, URPF, AARF

Network Reliability

HA, ULFD, G.8032, ULPP, Monitor Link, VRRP, VRRPv3, VBRP, BFD, EEP, CPU protection

Management and Monitoring

Network Management

SNMP v1/v2/v3, MIB, RMON, SYSLOG, DNS, CLI, Telnet, FTP/TFTP, Debug, NTP, Keepalive Gateway

Network Monitoring

SPAN, RSPAN, IPFIX, Netconf, sFlow, LLDP, IP-SLA, CWMP, NDSP, Telemetry, OAM

         

 

Power Consumption Specification

Model Name

Max. Power Consumption

Model Name

Max. Power Consumption

NSM66-MPUB

42W

NSM66-MPUE

55W

NSM66-SFUB

125W

NSM66-SFUD

150W

FAN-05C-01B

47W

FAN-11A-01

50W

FAN-15B-01

75W

NSM66-16XGEF-EA

55W

NSM66-48GET4XGEF-EA

65W

NSM66-16XGEF-EB

61W

NSM66-48GEF4XGEF-EA

100W

NSM66-32XGEF-EB

110W

NSM66-24GET24GEF4XF-EA

85W

NSM66-48XGEF-EB

145W

NSM66-48GEF4XGEF-EB

110W

NSM66-16XGEF4QXGE-EB

92W

NSM66-48GET4XGEF-EB

72W

NSM66-8QXGE-EB

74W

NSM66-24GET24GEF4XF-EB

94W

NSM66-12QXGE-EB

111W

NSM66-40GETP8LTP4XF-EB

67W
(Not including PoE)

 

 

Typical Application

SDN Campus Network

 

NSS6600-application.jpg

Order Information

Model

Description

NSS6600-04 Host

NSS6600-04

V1 Version: NSS6600-04 chassis, two control engine slots, four service slots, one fan slot, two power slots.

NSM66-MPUB

V1 Version: NSM66-MPUB Control Engine, supporting active/standby backup function (one is mandatory, 1+1 redundancy is optional) For NSS6600-04

FAN-05C-01B

V1 Version: FAN-05C-01B Fan Module for NSS6600-04

AD500M-HS0F

V1 Version: AD500M-HS0F,500W AC power module

NSS6600-04 Line Cards

NSM66-16XGEF-EA

V1 Version: 16-Port 10G SFP+ interfaces line card

NSM66-24GET24GEF4XF-EA

V1 Version: 24-Port 100/1000M electric interfaces, 24-Port 1000M SFP interfaces, 4-Port 10G SFP+ interfaces line card

NSM66-48GEF4XGEF-EA

V1 Version: 48-Port 1000M SFP interfaces, 4-Port 10G SFP+ interfaces line card

NSM66-48GET4XGEF-EA

V1 Version: 48-Port 100/1000M electric interfaces, 4-Port 10G SFP+ interfaces line card

NSS6600-06 Host

NSS6600-06

V2 Version: NSS6600-06 chassis, two control engine slots, two switching engine slots, four service slots, two fan slots, four power slots.

NSM66-MPUE

V2 Version: NSM66-MPUE Control Engine, for NSS6600-06/10, supporting active/standby backup function

NSM66-SFUB

V2 Version: NSM66-SFUB Standard Switching Engine, for NSS6600-06/10

NSM66-SFUD

V2 Version: NSM66-SFUD Advanced Switching Engine, for NSS6600-06/10

FAN-11A-01

V1 Version: FAN-11A-01 Fan module for NSS6600-06

AD800-1D005M

V1 Version: AD800-1D005M, 800W AC power module

AD1600-1D005M

V2 Version: AD1600-1D005M, 1600W AC power module

NSS6600-10 Host

NSS6600-10

V2 Version: NSS6600-10 chassis, two control engine slots, two switching engine slots, eight service slots, two fan slots, four power slots.

NSM66-MPUE

V2 Version: NSM66-MPUE Control Engine, for NSS6600-06/10, supporting active/standby backup function

NSM66-SFUB

V2 Version: NSM66-SFUB Standard Switching Engine, for NSS6600-06/10

NSM66-SFUD

V2 Version: NSM66-SFUD Advanced Switching Engine, for NSS6600-06/10

FAN-15B-01

V1 Version: FAN-15B-01 Fan module for NSS6600-10

AD800-1D005M

V1 Version: AD800-1D005M, 800W AC power module

AD1600-1D005M

V2 Version: AD1600-1D005M, 1600W AC power module

NSS6600-06/10 Line Cards

NSM66-12QXGE-EB

V2 Version:12-Port 40G QSFP+ interfaces line card
(Note: Configure 2*NSM66-SFUD Switching Engines)

NSM66-48XGEF-EB

V2 Version:48-Port 10G SFP+ interfaces line card
(Note: Configure 2*NSM66-SFUD Switching Engines)

NSM66-8QXGE-EB

V2 Version:8-Port 40G QSFP+ interfaces line card
(Note: Configure 2*NSM66-SFUD Switching Engines)

NSM66-32XGEF-EB

V2 Version:32-Port 10G SFP+ interfaces line card
(Note: Configure 2*NSM66-SFUD Switching Engines)

NSM66-16XGEF4QXGE-EB

V2 Version:16-Port 10G SFP+ interfaces, 4-Port 40G QSFP+ interfaces line card
(Note: Configure 2*NSM66-SFUD Switching Engines)

NSM66-16XGEF-EB

V2 Version:16-Port 10G SFP+ interfaces line card
(Note: Configure 2*NSM66-SFUB Switching Engines)

NSM66-48GEF4XGEF-EB

V2 Version:48-Port 1000M SFP interfaces, 4-Port 10G SFP+ interfaces line card
(Note: Configure 2*NSM66-SFUB Switching Engines)

NSM66-48GET4XGEF-EB

V2 Version:48-Port 100/1000M electric interfaces, 4-Port 10G SFP+ interfaces line card (Note: Configure 2*NSM66-SFUB Switching Engines)

NSM66-24GET24GEF4XF-EB

V2 Version:24-Port 100/1000M electric interfaces, 24-Port 1000M SFP interfaces, 4-Port 10G SFP+ interfaces line card
(Note: Configure 2*NSM66-SFUB Switching Engines)

NSM66-40GETP8LTP4XF-EB

V2 Version:40-Port 100/1000M electric PoE+ interfaces (Support 802.3af/at), 8-Port 100/1000M/2.5G electric PoE++ interfaces (Support 802.3af/at/bt), 4-Port 10G SFP+ interfaces line card
(Note: Configure 2*NSM66-SFUB Switching Engines)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NSS6600 Series L3 SDN Distribution Switch Datasheet-20250407