NSS18500 Series Data Center Switch
NSS18500 series switches are Maipu new generation 100GE Ethernet switches designed for enterprise data center and large campus networks, providing high-throughput, high-density 1G/10GE/40GE/100GE interfaces, larger interface buffer and lower latency. The NSS18500 series adopts advanced crossbar hardware architecture. By using Maipu MyPowerOS software platform, NSS18500 series provide rich data center service features and management capability.
NSS18500 series switches adopt an advanced hardware architecture design. It provides up to 288*100GE, 272*40GE, 384*10GE, 384*1GE line-rate ports and use an industry-leading Crossbar architecture and provide industrial-grade reliability. The switches support comprehensive data center service features. Their front-to-back airflow design suits data center equipment rooms, and the innovative energy conservation technologies greatly reduce power consumption.
NSS18500 series switches can build a complete, scalable, virtualized fabric network that meets the data center requirements. Meanwhile, NSS18500 can also be deployed as core switches for large enterprise campus networks.
NSS18500 series includes NSS18500-04, NSS18500-08 two models:
NSS18500-04 supports dual control engines, 6 switching fabrics and 4 service slots.
NSS18500-08 supports dual control engines, 6 switching fabrics and 8 service slots.
(Note: The product information may not be latest. For the latest, please contact overseas@maipu.com)
Product Features
l High-Density Interfaces Line Cards
NSS18500 series provide maximum 288*100GE, 272*40GE, 384*10GE, 384*1GE interfaces and use an industry-leading crossbar architecture. The port combination fully satisfies the interface density requirement of data center and campus network scenarios.
l Highly Reliable Enterprise-class Hardware Design
NSS18500 has enterprise-class reliability and stability to ensure long-term service continuity. Redundant MPUs work in 1+1 hot backup mode. Redundant SFUs work in N+M hot backup mode. Redundant power supplies support work in N+M hot backup and also redundant fan trays design. The fan trays work in 1+1 backup mode to ensuring efficient heat dissipation.
l M-LAG for cross-device link aggregation
NSS18500 series support multi-chassis link aggregation group (M-LAG), which enables links of multiple switches to aggregate into one to implement cross-device link backup. The rest of switches in the M-LAG group are working actively regardless any switch failure. During the upgrade, other switches in the system take over traffic forwarding to ensure uninterrupted services.
l VxLAN and EVPN for L2 Virtualized Deployment
NSS18500 series can work with the industry's mainstream virtualization platforms and acts a hardware gateway on a VxLAN overlay network. Virtual extensible LANs (VxLAN), a common network virtualization overlay protocol that expands the layer 2 network address space from 4,000 to 16 million. NSS18500 series support BGP-EVPN, which is used as the overlay control plane and provides virtual connectivity between different layer 2/3 domains over an IP network.
l RoCEv2 Standard Compliance
NSS18500 series fully support the RoCEv2 standards, meeting the requirements for switch performance in high-performance data center scenarios. NSS18500 series supports a wide range of lossless Ethernet technologies, including ETS, PFC, ECN, DCBX, etc. This helps create an end-to-end, zero-jitter, low-latency, lossless Ethernet network that meets the demands of cloud computing, big data, artificial intelligence, and high-performance computing deployments in data centers.
l Southbound and Northbound API
NSS18500 series support NETCONF and RESTCONF API which can work with 3rd party SDN controller for simplified device remote configuration and management.
l Telemetry for intelligent OAM
NSS18500 provides telemetry technology to collect device data in real time and send the management data to customer network analyzer platform. Telemetry systems, done properly, play an important role in providing you with information about the health of your network, so you can respond intelligently to prevent hardware failure and network downtime. It can help customers to identify and analyze network problems which affect user experience.
l Reliable hardware design and energy-saving
NSS18500 series use a standard airflow design which isolates cold air channels from hot air channels. This design improves heat dissipation efficiency and meets design requirements of data center. It adopts hot swap redundant power modules and fans which ensure hardware reliability and non-stopping operation. The fan speed can be adjusted dynamically based on system workload. NSS18500 series have energy-saving chipsets with EEE technology and can save system power consumption in real time.
l Free Licensing Policy
Maipu always insists on “One-time investment” free license policy, the standard features and advanced features will be never divided to different version. For any new firmware version, Maipu will share to customers without extra charge. Compared with other manufacturers, Maipu free license policy can better protect users' short-term and long-term investment.
Product Specifications
Product Model |
NSS18500-04 |
NSS18500-08 |
||
Hardware specification |
||||
Hardware Architecture |
CLOS |
CLOS |
||
Control Engine Slots |
2 |
2 |
||
Switching Engine Slots |
4*SFUA Slots 2*SFUA-EX Slots |
4*SFUB/C Slots 2*SFUC-EX Slots |
||
Service Card Slots |
4 |
8 |
||
Control Engine Model |
NSM185-MPUA |
NSM185-MPUB |
||
Switching Engine Model |
NSM185-SFUA NSM185-SFUA-EX |
NSM185-SFUB NSM185-SFUC NSM185-SFUC-EX |
||
Max. Switching Capacity |
28.8Tbps |
57.6Tbps |
||
Flash |
8G |
|||
Memory |
4G(Default)/8G |
|||
Interface Buffer Size |
32M |
|||
Jumbo Frame |
12K |
|||
MAC Address Entry |
224K/720K |
|||
ARP Entry |
56K/106K |
|||
IPv4 Routing Entry |
294K/660K |
|||
MSTP Instance |
64 |
|||
VRF Entry |
4K/8K |
|||
VRRP Group |
255 |
|||
Max. ECMP Path |
64 |
|||
IGMP Group |
8K |
|||
VxLAN VTEP Instance |
8K |
|||
EVPN L3 Route Entry |
56K |
|||
Power Slots |
4 |
8 |
||
FAN Slots |
2 |
2 |
||
Air Flow |
Front-to-Back |
Front-to-Back |
||
Power Input |
Input voltage AC: 100V ~ 240V, 50Hz ~ 60Hz |
|||
Input voltage DC:42V~72V Or Input High voltage DC: 192V~288V |
||||
Temperature |
Work temperature: 0℃ to 50℃ |
|||
Storage temperature: -40℃ to 70℃ |
||||
Humidity |
Work humidity: 10% to 90%, no-condensing |
|||
Storage humidity: 5% to 95%, no-condensing |
||||
Dimension(W×D×H) |
442mm×747.5mm×262.5mm(6U) |
442mm×645mm×666mm(15U) |
||
MTBF |
>100, 000 hours |
|||
Software specification |
||||
Standard L2 Protocol |
Interface |
Port Type UNI/NNI, Port Speed, Port MTU, Port Loopback, Loopback interface, Tunnel interface, Null interface, VXLAN interface, VXLAN distribute-gateway |
||
Ethernet Switching |
LACP Link aggregation, LACP Port Priority, LACP Load Balance, LACP Rate Monitor, LACP Debug, Port isolation, QinQ, VLAN mapping, Super VLAN, PVLAN, Voice VLAN, STP, RSTP, MSTP, Loopback-detection, Error-disable, VIST/VISR+, GVRP, MLAG, VLAN isolation |
|||
Standard L3 Protocol |
IP Protocol |
ARP, DHCP, DHCPv6, DHCP Server, DHCPv6 Server, DHCPv6 Client, DHCP Relay, DHCPv6 Relay, DHCP Option82, DNS, GRE, IPIP, IPv6 over IPv4, ISATAP, IPv4 over IPv6, IPv6 over IPv6 |
||
Routing Protocol |
Static route for IPv4&IPv6, RIPv1/v2, RIPng, OSPFv2, OSPFv3, IS-IS, IS-ISv6, IRMP, BGP, BGPv6, Policy Route, MP-BGP |
|||
Multicast |
L2 Multicast |
IGMPv1/v2/v3 Snooping, IGMP Snooping over VxLAN, multicast VLAN(MVR, MVP), MLD Snooping, Router-alert Option |
||
L3 Multicast |
IGMPv1/v2/v3, MLDv1/v2, PIM-SM, IPv6 PIM-SM, PIM-DM, PIM-SSM, IPv6 PIM-SSM, MSDP, IGMP Group Filter, MLD Group Filter |
|||
QoS & ACL |
QoS |
802.1p, DSCP, Priority mapping, SP, WRR, WRED, WDRR, SP+WRR, SP+WDRR, Flow classification, Traffic monitoring, Traffic shaping, Congestion management, Congestion avoidance, Flow-based mirroring |
||
ACL |
Standard IP ACL, extended IP ACL, standard MAC ACL, extended MAC ACL, extended Hybrid ACL, Standard IPv6 ACL, extended IPv6 ACL |
|||
Data Center Feature |
Basic Feature |
TRILL, VXLAN, ESI Multi-Homing, BGP-EVPN, NLB, OpenFlow |
||
RoCEv2 |
ECN, ETS, PFC, iNOF, DCBX |
|||
MPLS L2/L3 VPN |
L3 MPLS VPN |
MPLS LDP, MPLS GR, M-VRF, MPLS L3 VPN, MPLS OAM, IPv6 MPLS L3VPN, MPLS TE, MPLS Qos |
||
L2 VPLS VPN |
VPWS, Martini/Kompella VPLS |
|||
Precision Time Protocol(PTP) |
IEEE 1588v2 |
E2ETC, P2PTC |
||
Virtualization |
VST |
H-VST, M-VST |
||
MAD |
MAD LACP, MAD BFD, MAD Fast-hello |
|||
Security & Network Reliability |
Security |
ARP Check, AARF, AARF ARP-Guard, CPU Protection, Port Security, IP Source Guard, IPv6 Source Guard, ND-Snooping, DHCP Snooping, DHCPv6 Snooping, Dynamic ARP Inspection (DAI), Host Guard, P2P MACSec, PPPoE+, 802.1x, Portal Authentication, Anti-attack detect|drop|flood|log, URPF |
||
AAA |
Authentication, Authorization, Accounting, Radius, TACACS+ |
|||
Network Reliability |
HA, ULFD, ERPS, ULPP, Monitor Link, VRRP, VRRPv3, VBRP, BFD, EEP, CPU protection |
|||
Management |
Network Management |
SNMP v1/v2/v3, MIB, RMON, SYSLOG, DNS, CLI, Telnet, SSH, HTTP/HTTPS, FTP/TFTP, Debug, NTP, Keepalive Gateway |
||
Network Monitoring |
SPAN, RSPAN, ERSPAN, VLAN SPAN, sFlow, IPFIX, LLDP, IP-SLA, CWMP, Telemetry, Netconf, Restconf, BSM, MOD, Capture-Packet |
Power Consumption Specification
Model Name |
Max. Power Consumption |
Model Name |
Max. Power Consumption |
NSM185-MPUA |
50W |
NSM185-MPUB |
50W |
NSM185-SFUA-EX |
105W |
NSM185-SFUC-EX |
150W |
NSM185-SFUA |
105W |
NSM185-SFUC |
150W |
FAN-06A-01B |
105W |
NSM185-SFUB |
85W |
NSM185-36QFP-DA |
350W |
FAN-15B-01B |
125W |
NSM185-24QFP-DA |
235W |
NSM185-34QXGE-DA |
275W |
NSM185-12QFP-DA |
120W |
NSM185-16QXGE-DA |
125W |
NSM185-48XGEF2QXGE-DA |
165W |
NSM185-48GET4XGEF-DA |
100W |
Typical Application
RoCEv2 Lossless Ethernet Solution for Data Center
RoCEv2 is a network protocol that enables servers in data centers to perform Remote Direct Memory Access (RDMA) directly over Ethernet. RoCEv2 benefits significantly from a lossless Ethernet environment because it relies on high reliability and low latency for performance efficiency. Lossless Ethernet technology ensures that RoCEv2 can deliver its full potential benefits by avoiding the typical challenges associated with standard Ethernet communications.
NSS18500 fully supports the RoCEv2 standards, meeting the requirements for switch performance in high-performance data center scenarios. NSS18500 supports a wide range of lossless Ethernet technologies, including ETS, PFC, ECN, DCBX, etc. This helps create an end-to-end, zero-jitter, low-latency, lossless Ethernet network that meets the demands of cloud computing, big data, artificial intelligence, and high-performance computing deployments in data centers.
Order Information
Model |
Description |
NSS18500 Series |
|
NSS18500-04 Host |
|
NSS18500-04 |
NSS18500-04 chassis, two control engine slots, six switching engine slots, four service slots, two fan slots, four power slots. |
NSM185-MPUA |
NSM185-MPUA Control Engine, for NSS18500-04, supporting active/standby backup function |
NSM185-SFUA-EX |
NSM185-SFUA-EX Switching Engine, for NSS18500-04 |
NSM185-SFUA |
NSM185-SFUA Switching Engine, for NSS18500-04 |
FAN-06A-01B |
FAN-06A-01B Fan module for NSS18500-04 |
AD800M-HV1B |
AD800-HV1B, 800W AC power module |
DD1600M-5V0B |
DD1600M-5V1F, 1600W DC power module |
NSS18500-04 Line Cards |
|
NSM185-36QFP-DA |
36-port 100GE QSFP28 interface line card |
NSM185-24QFP-DA |
24-port 100GE QSFP28 interface line card |
NSM185-12QFP-DA |
12-port 100GE QSFP28 interface line card |
NSM185-34QXGE-DA |
34-port 40GE QSFP+ interface line card |
NSM185-16QXGE-DA |
16-port 40GE QSFP+ interface line card |
NSM185-48XGEF2QXGE-DA |
48-port 10GE SFP+ interface, 2-port 40GE QSFP+ interface line card |
NSM185-48GET4XGEF-DA |
48-port 1G Base-T electrical interface, 4-port 10GE SPF+ interface line card |
NSS18500-08 Host |
|
NSS18500-08 |
NSS18500-08 chassis, two control engine slots, six switching engine slots, eight service slots, two fan slots, eight power slots. |
NSM185-MPUB |
NSM185-MPUB Control Engine, for NSS18500-08, supporting active/standby backup function |
NSM185-SFUC-EX |
NSM185-SFUC-EX Switching Engine, for NSS18500-08 |
NSM185-SFUC |
NSM185-SFUC Switching Engine, for NSS18500-08 |
NSM185-SFUB |
NSM185-SFUB Switching Engine, for NSS18500-08 |
FAN-15B-01B |
FAN-15B-01B Fan module for NSS18500-08 |
AD800-1D005M |
AD800-1D005M, 800W AC power module |
DD1600M-5V1F |
DD1600M-5V1F, 1600W DC power module |
NSS18500-08 Line Cards |
|
NSM185-36QFP-DA |
36-port 100GE QSFP28 interface line card |
NSM185-24QFP-DA |
24-port 100GE QSFP28 interface line card |
NSM185-34QXGE-DA |
34-port 40GE QSFP+ interface line card |
NSM185-12QFP-DA |
12-port 100GE QSFP28 interface line card |
NSM185-16QXGE-DA |
16-port 40GE QSFP+ interface line card |
NSM185-48XGEF2QXGE-DA |
48-port 10GE SFP+ interface, 2-port 40GE QSFP+ interface line card |
NSM185-48GET4XGEF-DA |
48-port 1G Base-T electrical interface, 4-port 10GE SPF+ interface line card |