maipu maipu

SEARCH
Switch > DataCenter Switch > NSS18500 Series Data Center Switch

NSS18500 Series Data Center Switch

NSS18500 series switches are Maipu new generation 100GE Ethernet switches designed for enterprise data center and large campus networks, providing high-throughput, high-density 1G/10GE/40GE/100GE interfaces, larger interface buffer and lower latency. The NSS18500 series adopts advanced crossbar hardware architecture. By using Maipu MyPowerOS software platform, NSS18500 series provide rich data center service features and management capability.

NSS18500 series switches adopt an advanced hardware architecture design. It provides up to 288*100GE, 272*40GE, 384*10GE, 384*1GE line-rate ports and use an industry-leading Crossbar architecture and provide industrial-grade reliability. The switches support comprehensive data center service features. Their front-to-back airflow design suits data center equipment rooms, and the innovative energy conservation technologies greatly reduce power consumption. 

NSS18500 series switches can build a complete, scalable, virtualized fabric network that meets the data center requirements. Meanwhile, NSS18500 can also be deployed as core switches for large enterprise campus networks.

NSS18500 series includes NSS18500-04, NSS18500-08 two models:

NSS18500-04 supports dual control engines, 6 switching fabrics and 4 service slots.

NSS18500-08 supports dual control engines, 6 switching fabrics and 8 service slots.

 

(Note: The product information may not be latest. For the latest, please contact overseas@maipu.com)

 

 

Product Features

l  High-Density Interfaces Line Cards

NSS18500 series provide maximum 288*100GE, 272*40GE, 384*10GE, 384*1GE interfaces and use an industry-leading crossbar architecture. The port combination fully satisfies the interface density requirement of data center and campus network scenarios.

l  Highly Reliable Enterprise-class Hardware Design

NSS18500 has enterprise-class reliability and stability to ensure long-term service continuity. Redundant MPUs work in 1+1 hot backup mode. Redundant SFUs work in N+M hot backup mode. Redundant power supplies support work in N+M hot backup and also redundant fan trays design. The fan trays work in 1+1 backup mode to ensuring efficient heat dissipation.

l  M-LAG for cross-device link aggregation

NSS18500 series support multi-chassis link aggregation group (M-LAG), which enables links of multiple switches to aggregate into one to implement cross-device link backup. The rest of switches in the M-LAG group are working actively regardless any switch failure. During the upgrade, other switches in the system take over traffic forwarding to ensure uninterrupted services.

l  VxLAN and EVPN for L2 Virtualized Deployment

NSS18500 series can work with the industry's mainstream virtualization platforms and acts a hardware gateway on a VxLAN overlay network. Virtual extensible LANs (VxLAN), a common network virtualization overlay protocol that expands the layer 2 network address space from 4,000 to 16 million.  NSS18500 series support BGP-EVPN, which is used as the overlay control plane and provides virtual connectivity between different layer 2/3 domains over an IP network.

l  RoCEv2 Standard Compliance

NSS18500 series fully support the RoCEv2 standards, meeting the requirements for switch performance in high-performance data center scenarios. NSS18500 series supports a wide range of lossless Ethernet technologies, including ETS, PFC, ECN, DCBX, etc. This helps create an end-to-end, zero-jitter, low-latency, lossless Ethernet network that meets the demands of cloud computing, big data, artificial intelligence, and high-performance computing deployments in data centers.

l  Southbound and Northbound API

NSS18500 series support NETCONF and RESTCONF API which can work with 3rd party SDN controller for simplified device remote configuration and management.

l  Telemetry for intelligent OAM

NSS18500 provides telemetry technology to collect device data in real time and send the management data to customer network analyzer platform. Telemetry systems, done properly, play an important role in providing you with information about the health of your network, so you can respond intelligently to prevent hardware failure and network downtime. It can help customers to identify and analyze network problems which affect user experience.

l  Reliable hardware design and energy-saving

NSS18500 series use a standard airflow design which isolates cold air channels from hot air channels. This design improves heat dissipation efficiency and meets design requirements of data center. It adopts hot swap redundant power modules and fans which ensure hardware reliability and non-stopping operation. The fan speed can be adjusted dynamically based on system workload. NSS18500 series have energy-saving chipsets with EEE technology and can save system power consumption in real time.

l   Free Licensing Policy

Maipu always insists on “One-time investment” free license policy, the standard features and advanced features will be never divided to different version. For any new firmware version, Maipu will share to customers without extra charge. Compared with other manufacturers, Maipu free license policy can better protect users' short-term and long-term investment.

Product Specifications

Product Model

NSS18500-04

NSS18500-08

Hardware specification 

Hardware Architecture

CLOS

CLOS

Control Engine Slots

2

2

Switching Engine Slots

4*SFUA Slots

2*SFUA-EX Slots

4*SFUB/C Slots

2*SFUC-EX Slots

Service Card Slots

4

8

Control Engine Model

NSM185-MPUA

NSM185-MPUB

Switching Engine Model

NSM185-SFUA

NSM185-SFUA-EX

NSM185-SFUB

NSM185-SFUC

NSM185-SFUC-EX

Max. Switching Capacity

28.8Tbps

57.6Tbps

Flash

8G

Memory

4G(Default)/8G

Interface Buffer Size

32M

Jumbo Frame

12K

MAC Address Entry

224K/720K

ARP Entry

56K/106K

IPv4 Routing Entry

294K/660K

MSTP Instance

64

VRF Entry

4K/8K

VRRP Group

255

Max. ECMP Path

64

IGMP Group

8K

VxLAN VTEP Instance

8K

EVPN L3 Route Entry

56K

Power Slots

4

8

FAN Slots

2

2

Air Flow

Front-to-Back

Front-to-Back

Power Input

Input voltage AC: 100V ~ 240V, 50Hz ~ 60Hz

Input voltage DC:42V~72V Or

Input High voltage DC: 192V~288V

Temperature

Work temperature: 0 to 50

Storage temperature: -40 to 70

Humidity

Work humidity: 10% to 90%, no-condensing

Storage humidity: 5% to 95%, no-condensing

Dimension(W×D×H)

442mm×747.5mm×262.5mm(6U)

442mm×645mm×666mm(15U)

MTBF

>100, 000 hours

Software specification 

Standard L2 Protocol

Interface

Port Type UNI/NNI, Port Speed, Port MTU, Port Loopback, Loopback interface, Tunnel interface, Null interface, VXLAN interface, VXLAN distribute-gateway

Ethernet Switching

LACP Link aggregation, LACP Port Priority, LACP Load Balance, LACP Rate Monitor, LACP Debug, Port isolation, QinQ, VLAN mapping, Super VLAN, PVLAN, Voice VLAN, STP, RSTP, MSTP, Loopback-detection, Error-disable, VIST/VISR+, GVRP, MLAG, VLAN isolation

Standard L3 Protocol

IP Protocol

ARP, DHCP, DHCPv6, DHCP Server, DHCPv6 Server, DHCPv6 Client, DHCP Relay, DHCPv6 Relay, DHCP Option82, DNS, GRE, IPIP, IPv6 over IPv4, ISATAP, IPv4 over IPv6, IPv6 over IPv6

Routing Protocol

Static route for IPv4&IPv6, RIPv1/v2, RIPng, OSPFv2, OSPFv3, IS-IS, IS-ISv6, IRMP, BGP, BGPv6, Policy Route, MP-BGP

Multicast

L2 Multicast

IGMPv1/v2/v3 Snooping, IGMP Snooping over VxLAN, multicast VLAN(MVR, MVP), MLD Snooping, Router-alert Option

L3 Multicast

IGMPv1/v2/v3, MLDv1/v2, PIM-SM, IPv6 PIM-SM, PIM-DM, PIM-SSM, IPv6 PIM-SSM, MSDP, IGMP Group Filter, MLD Group Filter

QoS & ACL

QoS

802.1p, DSCP, Priority mapping, SP, WRR, WRED, WDRR, SP+WRR, SP+WDRR, Flow classification, Traffic monitoring, Traffic shaping, Congestion management, Congestion avoidance, Flow-based mirroring

ACL

Standard IP ACL, extended IP ACL, standard MAC ACL, extended MAC ACL, extended Hybrid ACL, Standard IPv6 ACL, extended IPv6 ACL

Data Center Feature

Basic Feature

TRILL, VXLAN, ESI  Multi-Homing, BGP-EVPN, NLB, OpenFlow

RoCEv2

ECN, ETS, PFC, iNOF, DCBX

MPLS L2/L3 VPN

L3 MPLS VPN

MPLS LDP, MPLS GR, M-VRF, MPLS L3 VPN, MPLS OAM, IPv6 MPLS L3VPN, MPLS TE, MPLS Qos

L2 VPLS VPN

VPWS, Martini/Kompella VPLS

Precision Time Protocol(PTP)

IEEE 1588v2

E2ETC, P2PTC

Virtualization

VST

H-VST, M-VST

MAD

MAD LACP, MAD BFD, MAD Fast-hello

Security & Network Reliability

Security

ARP Check, AARF, AARF ARP-Guard, CPU Protection, Port Security, IP Source Guard, IPv6 Source Guard, ND-Snooping, DHCP Snooping, DHCPv6 Snooping, Dynamic ARP Inspection (DAI), Host Guard, P2P MACSec, PPPoE+, 802.1x, Portal Authentication, Anti-attack detect|drop|flood|log, URPF

AAA

Authentication, Authorization, Accounting, Radius, TACACS+

Network Reliability

HA, ULFD, ERPS, ULPP, Monitor Link, VRRP, VRRPv3, VBRP, BFD, EEP, CPU protection

Management

Network Management

SNMP v1/v2/v3, MIB, RMON, SYSLOG, DNS, CLI, Telnet, SSH, HTTP/HTTPS, FTP/TFTP, Debug, NTP, Keepalive Gateway

Network Monitoring

SPAN, RSPAN, ERSPAN, VLAN SPAN, sFlow, IPFIX, LLDP, IP-SLA, CWMP, Telemetry, Netconf, Restconf, BSM, MOD, Capture-Packet

 

Power Consumption Specification

Model Name

Max. Power Consumption

Model Name

Max. Power Consumption

NSM185-MPUA

50W

NSM185-MPUB

50W

NSM185-SFUA-EX

105W

NSM185-SFUC-EX

150W

NSM185-SFUA

105W

NSM185-SFUC

150W

FAN-06A-01B

105W

NSM185-SFUB

85W

NSM185-36QFP-DA

350W

FAN-15B-01B

125W

NSM185-24QFP-DA

235W

NSM185-34QXGE-DA

275W

NSM185-12QFP-DA

120W

NSM185-16QXGE-DA

125W

NSM185-48XGEF2QXGE-DA

165W

NSM185-48GET4XGEF-DA

100W

Typical Application

RoCEv2 Lossless Ethernet Solution for Data Center

RoCEv2 is a network protocol that enables servers in data centers to perform Remote Direct Memory Access (RDMA) directly over Ethernet. RoCEv2 benefits significantly from a lossless Ethernet environment because it relies on high reliability and low latency for performance eciency. Lossless Ethernet technology ensures that RoCEv2 can deliver its full potential benefits by avoiding the typical challenges associated with standard Ethernet communications.

NSS18500 fully supports the RoCEv2 standards, meeting the requirements for switch performance in high-performance data center scenarios. NSS18500 supports a wide range of lossless Ethernet technologies, including ETS, PFC, ECN, DCBX, etc. This helps create an end-to-end, zero-jitter, low-latency, lossless Ethernet network that meets the demands of cloud computing, big data, artificial intelligence, and high-performance computing deployments in data centers.

 

Order Information

Model

Description

NSS18500 Series

NSS18500-04 Host

NSS18500-04

NSS18500-04 chassis, two control engine slots, six switching engine slots, four service slots, two fan slots, four power slots.

NSM185-MPUA

NSM185-MPUA Control Engine, for NSS18500-04, supporting active/standby backup function

NSM185-SFUA-EX

NSM185-SFUA-EX Switching Engine, for NSS18500-04

NSM185-SFUA

NSM185-SFUA Switching Engine, for NSS18500-04

FAN-06A-01B

FAN-06A-01B Fan module for NSS18500-04

AD800M-HV1B

AD800-HV1B, 800W AC power module

DD1600M-5V0B

DD1600M-5V1F, 1600W DC power module

NSS18500-04 Line Cards

NSM185-36QFP-DA

36-port 100GE QSFP28 interface line card
(Recommended 4*
NSM185-SFUA+2*NSM185-SFUA-EX Switching Engines)

NSM185-24QFP-DA

24-port 100GE QSFP28 interface line card
(Recommended 4*
NSM185-SFUA+2*NSM185-SFUA-EX Switching Engines)

NSM185-12QFP-DA

12-port 100GE QSFP28 interface line card
(Recommended 4*
NSM185-SFUA Switching Engines)

NSM185-34QXGE-DA

34-port 40GE QSFP+ interface line card
(Recommended 4*
NSM185-SFUA Switching Engines)

NSM185-16QXGE-DA

16-port 40GE QSFP+ interface line card
(Recommended 4*
NSM185-SFUA Switching Engines)

NSM185-48XGEF2QXGE-DA

48-port 10GE SFP+ interface, 2-port 40GE QSFP+ interface line card
(Recommended 4*
NSM185-SFUA Switching Engines)

NSM185-48GET4XGEF-DA

48-port 1G Base-T electrical interface, 4-port 10GE SPF+ interface line card
(Recommended 2*
NSM185-SFUA Switching Engines)

NSS18500-08 Host

NSS18500-08

NSS18500-08 chassis, two control engine slots, six switching engine slots, eight service slots, two fan slots, eight power slots.

NSM185-MPUB

NSM185-MPUB Control Engine, for NSS18500-08, supporting active/standby backup function

NSM185-SFUC-EX

NSM185-SFUC-EX Switching Engine, for NSS18500-08

NSM185-SFUC

NSM185-SFUC Switching Engine, for NSS18500-08

NSM185-SFUB

NSM185-SFUB Switching Engine, for NSS18500-08

FAN-15B-01B

FAN-15B-01B Fan module for NSS18500-08

AD800-1D005M

AD800-1D005M, 800W AC power module

DD1600M-5V1F

DD1600M-5V1F, 1600W DC power module

NSS18500-08 Line Cards

NSM185-36QFP-DA

36-port 100GE QSFP28 interface line card
(Recommended 4*NSM185-SFUC+2*NSM185-SFUC-EX Switching Engines)

NSM185-24QFP-DA

24-port 100GE QSFP28 interface line card
(
Recommended 4*NSM185-SFUC+2*NSM185-SFUC-EX Switching Engines)

NSM185-34QXGE-DA

34-port 40GE QSFP+ interface line card
(Recommended 4*
NSM185-SFUC Switching Engines)

NSM185-12QFP-DA

12-port 100GE QSFP28 interface line card
(Recommended 4*
NSM185-SFUB Switching Engines)

NSM185-16QXGE-DA

16-port 40GE QSFP+ interface line card
(Recommended 4*
NSM185-SFUB Switching Engines)

NSM185-48XGEF2QXGE-DA

48-port 10GE SFP+ interface, 2-port 40GE QSFP+ interface line card
(Recommended 4*
NSM185-SFUB Switching Engines)

NSM185-48GET4XGEF-DA

48-port 1G Base-T electrical interface, 4-port 10GE SPF+ interface line card
(Recommended 2*
NSM185-SFUB Switching Engines)

 

:NSS18500 Series Data Center Core Switch Datasheet-20250427