NSS5950-04C Data Center Switch
The NSS5950-04C data center flexible modular switch is a next-generation Ethernet switching product developed by Maipu for next-generation data centers, featuring high performance, business flexibility, and low latency.
The NSS5950-04C offers ultra-high density and space-saving design, providing various port speeds such as 1G/10G/25G/40G/100G, and supports a rich set of data center features, meeting the demands for high-performance forwarding. Its modular card design is flexible and adaptable, offering exceptional versatility across multiple scenarios, including integrated access, interconnection gateway, dedicated line access, data center aggregation and core, storage-integrated devices, among others. It can also cater to next-generation campus networks with high-density access, aggregation, core, and simplified network deployment requirements.
The NSS5950-04C provides comprehensive, secure, controllable, stable, and reliable high-performance switching services, covering everything from chip design to hardware and software. It is well-suited for industries such as finance, government, telecommunications, energy, transportation, education, healthcare, and more.
(Note: The product information may not be latest. For the latest, please contact overseas@maipu.com)
Product Features
· Flexible Port Combination for Easy Expansion
The NSS5950-04C data center flexible modular switch supports high-density 1G/10G/25G/40G/100G ports and allows flexible combinations of various port types. The device can support up to 100*10G/25G ports, 64*40G ports, or 32*100G ports. This meets the high-speed interconnection demands of data centers, eliminates bandwidth bottlenecks, and supports network upgrades for the next 3 to 5 years.
· Simplified and Flexible Network Deployment to Reduce Complexity
The NSS5950-04C enables easy deployment based on high-density access points and supports simplified network architecture, greatly enhancing access and aggregation capabilities while reducing the number of network layers and devices. This brings unprecedented convenience and efficiency to campus networks. Its high-performance and high-density features make it an ideal choice for aggregation and core layers in data centers, enabling box-to-box network architectures. Compared to traditional modular switch solutions, it significantly reduces network complexity and latency in data centers.
· Supports RoCE for Building Zero-Jitter, Low-Latency Networks
The NSS5950-04C core data center switch supports lossless Ethernet DCB (Data Center Bridging) technology, addressing packet loss issues due to congestion in traditional Ethernet networks. It provides a lossless, low-latency, and high-throughput network environment for RoCEv2 applications, meeting high-performance demands. Based on ECN (Explicit Congestion Notification), which is a congestion control technology, and using ETS (Enhanced Transmission Selection) for two-level scheduling, it controls the total data entering the network to prevent congestion. Combined with RoCE NICs, it enables end-to-end RoCE, increasing data transmission throughput, reducing network latency, and lowering CPU load. This helps create an end-to-end, zero-jitter, low-latency, lossless Ethernet network that meets the demands of cloud computing, big data, artificial intelligence, and high-performance computing deployments in data centers.
· Integration and Openness with Exceptional Adaptability
The NSS5950-04C offers exceptional adaptability for both data center and campus network scenarios.
In campus networks, it provides high-density interface access capabilities, delivering unmatched convenience and efficiency. In interconnection and dedicated line hubs, it offers a wide range of port options from 1GE to 100GE, ensuring smooth data traffic at high volumes. In integrated access zones, it efficiently supports seamless integration for security devices and various systems. In data centers, it provides robust performance for both aggregation and core layers, offering continuous power for network demands.
The NSS5950-04C is also highly open, seamlessly integrating into various converged infrastructure scenarios (storage/database/hyper-converged systems). It supports open platforms like ONIE (Open Network Install Environment) and Sonic (Software for Open Networking in the Cloud), empowering users to easily build more flexible, intelligent, and efficient data centers and campus networks based on cloud-native and open network architectures.
Product Specifications
Product Model |
NSS5950-04C |
|
Hardware specification |
||
Line Card Slots |
4 |
|
Fixed Service Interfaces |
4*10G SFP+ |
|
Management interface |
1* RJ45 Console Port, 1*RJ45 DC0 Management Ethernet Port, 1*USB Port |
|
Switching capacity |
6.4Tbps |
|
Flash |
8G |
|
Memory |
4G(Default) |
|
Interface Buffer Size |
32M |
|
Jumbo Frame |
12K |
|
MAC Address Entry |
224K/720K |
|
ARP Entry |
56K/106K |
|
IPv4 Routing Entry |
294K/660K |
|
MSTP Instance |
64 |
|
VRF Entry |
4K/8K |
|
VRRP Group |
255 |
|
Max. ECMP Path |
64 |
|
IGMP Group |
8K |
|
VxLAN VTEP Instance |
8K |
|
EVPN L3 Route Entry |
56K |
|
Redundant design |
Support power redundancy, 1+1 backup mode |
|
Power Supply |
Two Power Slots |
|
Input voltage (AC): 100V ~ 240V, 50Hz ~ 60Hz |
||
Temperature |
Work temperature: 0℃ to 45℃ |
|
Storage temperature: -40℃ to 70℃ |
||
Humidity |
Work humidity: 10% to 90%, no-condensing |
|
Storage humidity: 5% to 95%, no-condensing |
||
Dimension(W×D×H) |
442mm×560mm×88.5mm |
|
MTBF |
>100, 000 hours |
|
Software specification |
||
Standard L2 protocol |
Interface |
Port Type UNI/NNI, Port Speed, Port MTU, Port Loopback, Loopback interface, Tunnel interface, Null interface, VXLAN interface |
Ethernet Switching |
LACP Link aggregation, LACP Port Priority, LACP Load Balance, LACP Rate Monitor, LACP Debug, Port isolation, QinQ, VLAN mapping, Super VLAN, PVLAN, Voice VLAN, STP, RSTP, MSTP, Loopback-detection, Error-disable, VIST/VISR+, GVRP, MLAG, MLAG Lite, VLAN isolation |
|
Standard L3 protocol |
IP Protocol |
ARP, DHCP, DHCPv6, DHCP Server, DHCPv6 Server, DHCPv6 Client, DHCP Relay, DHCPv6 Relay, DHCP Option82, DNS, GRE, IPIP, IPv6 over IPv4, ISATAP, IPv4 over IPv6, IPv6 over IPv6 |
Routing Protocol |
Static route for IPv4&IPv6, RIPv1/v2, RIPng, OSPFv2, OSPFv3, IS-IS, IS-ISv6, BGP, BGPv6, Policy Route, MP-BGP |
|
Multicast |
L2 multicast |
IGMP Snooping, IGMP Snooping over VxLAN, multicast VLAN (MVR, MVP), MLD Snooping, Router-alert Option |
L3 multicast |
IGMPv1/v2/v3, MLDv1/v2, PIM-SM, PIM-DM, PIM-SSM, IPv6 PIM-SM, IPv6 PIM-SSM, MSDP, IGMP Group Filter, MLD Group Filter |
|
QoS & ACL |
QoS |
802.1p, DSCP, Priority Mapping, SP, WRR, WDRR, SP+WRR, SP+WDRR, WRED, Flow classification, Traffic monitoring, Traffic shaping, Congestion management, Congestion avoidance, Flow-based mirroring |
ACL |
Standard IP ACL, extended IP ACL, standard MAC ACL, extended MAC ACL, extended Hybrid ACL, Standard IPv6 ACL, extended IPv6 ACL |
|
Data center feature |
Data center feature |
TRILL, VXLAN, BGP-EVPN, NLB, ECN, ETS, PFC, OpenFlow |
MPLS |
BGP MPLS |
MPLS LDP, MPLS GR, M-VRF, MPLS L3VPN, MPLS OAM, IPv6 MPLS L3VPN |
Virtualization |
VST |
H-VST, M-VST |
MAD |
MAD LACP, MAD BFD, MAD Fast-hello |
|
Security & Network Reliability |
Security |
ARP Check, AARF, AARF ARP-Guard, CPU Protection, Port Security, IP Source Guard, IPv6 Source Guard, ND-Snooping, DHCP Snooping, DHCPv6 Snooping, Dynamic ARP Inspection (DAI), AARF, Host Guard, PPPoE+, 802.1x, Portal Authentication, Anti-attack detect|drop|flood|log, URPF |
AAA |
Authentication, Authorization, Accounting, Radius, TACACS+ |
|
Network Reliability |
HA, ULFD, ERPS, ULPP, Monitor Link, VRRP, VRRPv3, VBRP, BFD, EEP, CPU Protection |
|
Management |
Network Management |
SNMP v1/v2/v3, MIB, RMON, SYSLOG, DNS, CLI, Telnet, SSH, HTTP/HTTPS, FTP/TFTP, Debug, NTP, Keepalive Gateway |
Network Monitoring |
SPAN, RSPAN, ERSPAN, VLAN SPAN, IPFIX, sFlow, LLDP, LLDP-MED, IP-SLA, CWMP, Telemetry, Netconf, BSM, MOD |
Typical Application
Enterprise Data Center VxLAN Application
Fabric architecture has become a common and popular design option for building new-generation enterprise data center networks. Virtual Extensible LAN (VXLAN) and Ethernet VPN (EVPN) is essentially becoming the standard technology used for deploying network virtualization overlays in data center LAN fabrics. NSS5950-04C switch support VxLAN and EVPN which is suitable to deploy in data center application as spine or leaf.
Order Information
Product model |
Description |
NSS5950 Series Host |
|
NSS5950-04C |
NSS5950-04C, 4*Service Slots, Fixed 4*10G SFP+ Ports, 3*Modular Fan Slots and 2*Modular Power Slots |
Service Card Modules |
|
NSM5-8MQS |
8*40/100G QSFP28 Ports Line Card |
NSM5-16MQF |
16*40G QSFP+ Ports Line Card |
NSM5-24FP2QS |
24*10/25G SFP28 and 2*40/100G QSFP28 Ports Line Card |
NSM5-24XF2QS |
24*1/10G SFP+ and 2*40/100G QSFP28 Ports Line Card |
NSM5-24FP |
24*10/25G SFP28 Ports Line Card |
NSM5-24XF |
24*1/10G SFP+ Ports Line Card |
FAN-02A-01B |
FAN-02A-01B, Modular Fan Slot, Hot-swappable, Air front in rear out |
FAN-02A-01F |
FAN-02A-01F, Modular Fan Slot, Hot-swappable, Air rear in front out |
Power Modules |
|
AD550M-HV0B |
V1 Version: AC input 100-240VAC/7A, 550W, output 12V/45A, current sharing, supporting hot-swap, Air front in rear out. (Note: Need work together with FAN-02A-01B) |
AD550M-HV0F |
V2 Version: AC input 100-240VAC/7A, 550W, output 12V/45A, current sharing, supporting hot-swap, Air rear in front out. (Note: Need work together with FAN-02A-01F) |
AD800M-HV0B |
V1 Version: AC input 100-240VAC/10A, 800W, output 12V/66A, current sharing, supporting hot-swap, Air front in rear out. (Note: Need work together with FAN-02A-01B) |
DD800M-5V0B |
V1 Version: DC input -40-72VDC/25A, 800W, output 12V/64A, current sharing, supporting hot-swap, Air front in rear out. (Note: Need work together with FAN-02A-01B) |