maipu maipu

SEARCH
Switch > DataCenter Switch > NSS5932 Series Data Center RoCE Switch

NSS5932 Series Data Center RoCE Switch

NSS5932 series switches are Maipu new generation 25GE data center RoCE switches designed for enterprise data center networks, providing high-throughput, high-density interfaces, larger buffer and lower latency. The NSS5932 series adopts advanced hardware architecture with 48*25GE access ports and 8*40/100GE uplinks. By using Maipu MyPowerOS software platform, NSS5932 series provide rich data center service features and management capability. 

NSS5932 series realize large buffer of the interfaces, meeting the burst flow forwarding without packet loss, provide the M-LAG technology for virtualization scenarios, provide the modular power and fan design for high reliability. The key components adopt "overvoltage" designs to ensure that the product has the strong ability of continuous operation. NSS5932 series can work with NSS5950 & NSS18500 spine switches to build a complete, scalable, virtualized RoCEv2 fabric network that meets the data center requirements.

NSS5932-48FP8QS supports 48*10/25G SFP28 optical interfaces, 8*40/100G QSFP28 optical interfaces, five modular fan slots, one modular multi-function slot and dual modular power slots.

Product Features

·       High-density 25GE Ports with 100GE Uplinks

NSS5932 series provide fixed 48*25GE interfaces in compact 1U device. The port combination fully satisfies the interface density requirement of data center scenarios. NSS5932 series have a maximum of 8*100GE QSFP28 uplinks, the uplink ports can be connected to NSS5950 & NSS18500 spine switches to build a non-blocking DC network architecture.

 ·       RoCEv2 Standard Compliance

NSS5932 series fully support the RoCEv2 standards, meeting the requirements for switch performance in high-performance data center scenarios. The NSS5932 supports a wide range of lossless Ethernet technologies, including PFC, ECN, ETS, DCBX, etc. This helps create an end-to-end, zero-jitter, low-latency, lossless Ethernet network that meets the demands of cloud computing, big data, artificial intelligence, and high-performance computing deployments in data centers.

 

 ·       M-LAG for Cross-device Link Aggregation

NSS5932 series support multi-chassis link aggregation group (M-LAG), which enables links of multiple switches to aggregate into one to implement cross-device link backup. The rest of switches in the M-LAG group are working actively regardless any switch failure. During the upgrade, other switches in the system take over traffic forwarding to ensure uninterrupted services.

 ·       VxLAN and EVPN for L2 Virtualized Deployment

NSS5932 series can work with the industry's mainstream virtualization platforms and acts a hardware gateway on an VxLAN overlay network. Virtual extensible LANs (VxLAN), a common network virtualization overlay protocol that expands the layer 2 network address space from 4,000 to 16 million.  NSS5932 series support BGP-EVPN, which is used as the overlay control plane and provides virtual connectivity between different layer 2/3 domains over an IP network.

 ·       Southbound and Northbound API

NSS5932 series support NETCONF and RESTCONF API which can work with 3rd party SDN controller for simplified device remote configuration and management.

 ·       Telemetry for Intelligent OAM

NSS5932 series provide telemetry technology to collect device data in real time and send the management data to customer network analyzer platform. Telemetry systems, done properly, play an important role in providing you with information about the health of your network, so you can respond intelligently to prevent hardware failure and network downtime. It can help customers to identify and analyze network problems which affect user experience.

 ·       Reliable Hardware Design

NSS5932 series use a standard airflow design which isolates cold air channels from hot air channels. This design improves heat dissipation efficiency and meets design requirements of data center. It adopts hot swap redundant power modules and fans which ensure hardware reliability and non-stopping operation. The fan speed can be adjusted dynamically based on system workload. 

 ·       Free Licensing Policy

Maipu always insists on “One-time investment” free license policy, the standard features and advanced features will be never divided to different version. For any new firmware version, Maipu will share to customers without extra charge. Compared with other manufacturers, Maipu free license policy can better protect users' short-term and long-term investment.

Product Specifications

Product Model

NSS5932-48FP8QS

Hardware Specification 

Physical Ports

Fixed 48*10/25G SFP28 optical interfaces, 8*40/100G QSFP28 optical interfaces

Management Interface

One console port, one management Ethernet port, one USB interface

Switching Capacity

4Tbps

Flash

8G

Memory

4G (Default)

Interface Buffer Size

16M

Jumbo Frame

12K

VLAN Entry

4094

Max. MAC Address Entry

448K

Max. ARP Entry

129K

Max. IPv4 Routing Entry

393K

Max. IPv6 Routing Entry

196K

Max. VRF Entry

8K

ECMP Path

128

VRRP Group

255

IGMP Group

8K

VxLAN VTEP Instance

8K

Power Supply Slot

2

Fan Module Slot

5

Multi-function Slot

1

Power Supply

Input voltage (AC): 100V ~ 240V, 50Hz ~ 60Hz

Input voltage (DC): -40~-72V

Temperature

Work temperature: 0 to 50

Storage temperature: -40 to 70

Humidity

Work humidity: 10% to 90%, no-condensing

Storage humidity: 5% to 95%, no-condensing

Power Consumption

220W

Dimension(W×D×H)

442mm×420mm×44.2mm

MTBF

>200, 000 hours

Software Specification 

Standard L2 Protocol

Interface

Port Type UNI/NNI, Port Speed, Port MTU, Port Loopback, Loopback interface, Tunnel interface, Null interface, VXLAN interface

Ethernet Switching

LACP Link aggregation, LACP Port Priority, LACP Load Balance, LACP Rate Monitor, LACP Debug, Port isolation, QinQ, VLAN mapping, Super VLAN, PVLAN, Voice VLAN, STP, RSTP, MSTP, Loopback-detection, Error-disable, VIST/VISR+, GVRP, MLAG, MLAG Lite, VLAN isolation

Standard L3 Protocol

IP Protocol

ARP, DHCP, DHCPv6, DHCP Server, DHCPv6 Server, DHCPv6 Client, DHCP Relay, DHCPv6 Relay, DHCP Option82, DNS, GRE, IPIP, IPv6 over IPv4, ISATAP, IPv4 over IPv6, IPv6 over IPv6

Routing Protocol

Static route for IPv4&IPv6, RIPv1/v2, RIPng, OSPFv2, OSPFv3, IS-IS, IS-ISv6, BGP, BGPv6, Policy Route, MP-BGP

Multicast

L2 Multicast

IGMP Snooping, IGMP Snooping over VxLAN, multicast VLAN (MVR, MVP), MLD Snooping, Router-alert Option

L3 Multicast

IGMPv1/v2/v3, MLDv1/v2, PIM-SM, PIM-DM, PIM-SSM, IPv6 PIM-SM, IPv6 PIM-SSM, MSDP, IGMP Group Filter, MLD Group Filter

QoS & ACL

QoS

802.1p, DSCP, Priority Mapping, SP, WRR, WDRR, SP+WRR, SP+WDRR, WRED, Flow classification, Traffic monitoring, Traffic shaping, Congestion management, Congestion avoidance, Flow-based mirroring

ACL

Standard IP ACL, extended IP ACL, standard MAC ACL, extended MAC ACL, extended Hybrid ACL, Standard IPv6 ACL, extended IPv6 ACL

Data Center Feature

Basic Feature

TRILL, VXLAN, M-LAG, MLAG for VXLAN, VXLAN QoS, ESI Multi-Homing, BGP-EVPN, NLB

RoCEv2

ECN, EQCN, ETS, PFC, iNOF, DCBX

MPLS L2/L3 VPN

L3 MPLS VPN

MPLS LDP, MPLS GR, M-VRF, MPLS L3VPN, Inter-AS MPLS VPN Option A/B, MPLS OAM, IPv6 MPLS L3VPN, MPLS TE, MPLS QoS

L2 VPLS VPN

VPWS, Martini/Kompella VPLS, H-VPLS

Precision Time Protocol

(PTP)

IEEE 1588v2

E2ETC, P2PTC

Virtualization

VST

H-VST, M-VST

MAD

MAD LACP, MAD BFD, MAD Fast-hello

Security & Network Reliability

Security

ARP Check, AARF, AARF ARP-Guard, CPU Protection, Port Security, IP Source Guard, IPv6 Source Guard, ND-Snooping, DHCP Snooping, DHCPv6 Snooping, Dynamic ARP Inspection (DAI), AARF, Host Guard, PPPoE+, 802.1x, Portal Authentication, Anti-attack detect|drop|flood|log, URPF

AAA

Authentication, Authorization, Accounting, Radius, TACACS+

Network Reliability

HA, ULFD, ERPS, ULPP, Monitor Link, VRRP, VRRPv3, VBRP, BFD, EEP, CPU protection

Management

Network Management

SNMP v1/v2/v3, MIB, RMON, SYSLOG, DNS, CLI, Telnet, SSH, HTTP/HTTPS, FTP/TFTP, Debug, NTP, Keepalive Gateway

Network Monitoring

SPAN, RSPAN, ERSPAN, VLAN SPAN, IPFIX, sFlow, LLDP, LLDP-MED, IP-SLA, CWMP, Telemetry, OpenFlow, Netconf, Restconf, BSM, MOD, Capture Packet

Typical Application

RoCEv2 Lossless Ethernet Solution for Data Center

RoCEv2 is a network protocol that enables servers in data centers to perform Remote Direct Memory Access (RDMA) directly over Ethernet. RoCEv2 benefits significantly from a lossless Ethernet environment because it relies on high reliability and low latency for performance efficiency. Lossless Ethernet technology ensures that RoCEv2 can deliver its full potential benefits by avoiding the typical challenges associated with standard Ethernet communications.

NSS5932 series fully support the RoCEv2 standards, meeting the requirements for switch performance in high-performance data center scenarios. The NSS5932 supports a wide range of lossless Ethernet technologies, including ETS, PFC, ECN, DCBX, etc. This helps create an end-to-end, zero-jitter, low-latency, lossless Ethernet network that meets the demands of cloud computing, big data, artificial intelligence, and high-performance computing deployments in data centers.

Order Information

Product model

Description

NSS5932 Series Host

NSS5932-48FP8QS

48-Port 25G SFP28 interfaces, 8-Port 100G QSFP28 interfaces, 5 Fan Slots, 1 Multi-function Slot, Dual Power Slots

Fan Modules

FAN-01J-01B

V1 Version: FAN-01J-01B, Modular Fan Slot, Hot-swappable, Air front in rear out

FAN-01J-01F

V1 Version: FAN-01J-01F, Modular Fan Slot, Hot-swappable, Air rear in front out

Power Modules

AD550M-HV0B

V3 Version: AC input 100-240VAC/7A, 550W, output 12V_45A, current sharing, supporting hot-swap, Air front in rear out. (Note: Need work together with FAN-01J-01B)

AD550M-HV0F

V3 Version: AC input 100-240VAC/7A, 550W, output 12V_45A, current sharing, supporting hot-swap, Air rear in front out. (Note: Need work together with FAN-01J-01F)

:NSS5932 Series RoCEv2 Data Center Switch Datasheet-20250912